Top Flue Tile Inspection Checklist
Flue tile extends between 2 -4 in above crown
Cracked flue requires replacement or repair
Flue must be 2 feet higher anything 10 feet away
Clay liners must be at least 5/8 inch thick
Flue liner joints between 1/16 – 1/8 inch
Liners installed ahead of construction
Space required around flue tile for thermal expansion
Space around flue no more than thickness of tile
Flue sized by fireplace opening (1/8, 1/10, 1/12)
Flue can be sized by IRC R1003.15.2 height chart
Masonry chimneys require chimney liners
Two+ liners need 4 inch separation wythe wall
Wood stoves require direct connect liner
Flue liners shall be maintained by filling voids
Code References
ASTM 1283 8.5 & NFPA 211 – 7.213.3
NFPA 211 – 14.9
R1003.9
NFPA 211 7.2.3
ASTM 1283 5.4
NFPA 211 – 7.2.10.1
ASTM 1283 8.4 & NFPA 211 – 7.2.12.1
ASTM 1283 5.6
R1003.15.1
R1003.15.2
R1003.11
R1003.13
NFPA 211 – 13.4.5 (1)
ASTM 1283 5.5